Using the Network Cable Tester is straightforward, and all testing could be done using the suspect cables in location. There isn't any require to reduce any so-installed cables from conduits for testing. Begin out by inserting one finish using the suspect cable into the jack in the loopback unit. Then visit the other finish with all the cable and insert it in the jack within the breakout unit.
Now, operating from the breakout Network Cable Tester, set your multimeter for continuity testing. Subsequent, insert one lead while using meter into hole #1 and also the other into hole #2, becoming bound to insert the test leads till readily available into get in touch with using the screw heads inside the terminal block. The meter really should indicate continuity in between the two of these points. Repeat the procedure utilizing holes #3 and #6. Again, the meter ought to indicate continuity. If both of those test show continuity to exist, the Network Cable Tester is intact and really should be usable. Any lack of continuity in the above tests indicates a faulty cable. Testing procedures are identical for straight-through and crossover Network Cable Tester.
Keep in mind that this specific process does need removing of installed cables, as you need to reach each ends at the moment together with your multimeter. It also demands that you prepare a second breakout unit as described in Actions 15 via 25 above. Merely connect 1 breakout unit to each finish with the cable and examine for continuity amongst each holes #1 of every breakout unit. If there??£¤s continuity from hole #1 to hole #1 together with the opposite unit, the cable is usually a straight-through Network Cable Tester.